Autodesk revit 2017 mep fundamentals pdf free.Revit Fundamentals

Looking for:

Autodesk revit 2017 mep fundamentals pdf free

Click here to Download

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Callouts, elevations, and sections are especially important views for construction documents. Learning Objectives in this Chapter • Change the way elements. Autodesk Revit MEPFundamentals SDCP U B L I C AT I O N SBetter Textbooks. Lower replace.me Visit the following websites to learn.
 
 

 

[Discover Autodesk Revit Books

 

About Parametric Modeling Relationships Parametric modeling refers to the relationships among all elements in a project that enable the coordination and change management that Revit provides. These relationships are created either automatically by the software or by you as you work. About Element Behavior in Revit Revit uses 3 types of elements in projects: model elements, datum elements, and view-specific elements.

Elements in Revit are also referred to as families. The family contains the geometric definition of the element and the parameters used by the element. Creating HVAC and plumbing systems with automatic duct and piping layouts. Testing duct, piping and electrical systems.

Creating and annotating construction documents. Adding tags and creating schedules. Detailing in the Autodesk Revit software. It is highly recommended that students have experience and knowledge in MEP engineering and its terminology. Search this site. Spreadsheet’s Bookshelf — 2f95dbccb1.

 
 

Autodesk revit 2017 mep fundamentals pdf free.

 
 

In the example shown in Figure 7—40, the front wall was selected. The view is limited to a box around the selected item s. Use the controls of the Section Box to modify the size of the box to show exactly what you want. There are other specific type options as well. Figure 7—41 Figure 7—42 Modifying Elevation Markers When you modify elevation markers, you can specify the length and depth of the clip plane, as shown in Figure 7— Arrow controls to adjust the depth of the To display additional interior elevations from one marker, select the circle portion not the arrowhead and place a checkmark in the directions that you want to display, as shown in Figure 7— Modifying Section Markers When you modify section markers, various shape handles and controls enable you to modify a section, as shown in Figure 7— Select it again to restore the full section cut.

Select the section line you want to modify. Select the point along the line where you want to create the split, as shown in Figure 7— Specify the location of the split line, as shown in Figure 7— Figure 7—48 To bring a split section line back into place, use a shape handle to drag the jogged line until it is at the same level with the rest of the line.

Hint: Using Thin Lines The software automatically applies line weights to views, as shown for a section on the left in Figure 7— If a line weight seems heavy or obscures your work on the elements, toggle off the line weights. The lines display with the same weight, as shown on the right in Figure 7— You will also add a Framing Elevation as shown in Figure 7— Figure 7—50 Task 1 – Create sections.

Open Practice-Model-Sections. Place a vertical section offset slightly from the middle. Change the width of the section using the controls as shown in Figure 7— Figure 7—51 5. Right-click on the new section and rename it Building Section, as shown in Figure 7— Open the new section by double-clicking on its name in the Project Browser. The entire Building displays as shown in Figure 7— Figure 7—53 7. Select the crop region and use the controls to shorten the section so that the curved walls to the left do not display, as shown in Figure 7— Figure 7—54 8.

The boundary of the section has changed as shown on the left in Figure 7— Use the circular control to move the section head down as shown on the right in Figure 7— Start the Section command again. Draw a short section through the wall as shown in Figure 7— Modify the section boundary so that it does not touch anything other than the wall.

Figure 7—56 Open the new section view. By default, the section expands the entire height of the project. Use the controls to resize the section so that only the foundation displays as shown in Figure 7— Figure 7—57 Task 2 – Add a framing elevation.

Open the Structural Plans: Level 1 view. Zoom in on the south wall of the building between columns 2 and 3. Hover the cursor over Grid D as shown in Figure 7— Pick a point when the elevation marker is on the outside of the building. Figure 7—58 5. Click on the pointer of the elevation marker. Expand the length of the elevation so that it is just on each side of the columns as shown in Figure 7— Figure 7—59 7. Open the framing elevation. Modify the size of the elevation to only display the bracing as shown in Figure 7— Figure 7—60 Return to the Structural Plans: Level 1 view.

Zoom out to display the entire building. In the Quick Access Toolbar, click Windows. Close Hidden Which of the following commands shown in Figure 7—61, creates a view that results in an independent view displaying the same model geometry and containing a copy of the annotation? Figure 7—61 a. Duplicate b. Duplicate with Detailing c. Duplicate as a Dependent 2. Which of the following is true about the Visibility Graphic Overrides dialog box?

Select all that apply. Changes made in the dialog box only affect the current view. It can only be used to toggle categories on and off. It can be used to toggle individual elements on and off.

It can be used to change the color of individual elements. The purpose of callouts is to create a I’d like to read this book on Kindle Don’t have a Kindle? Virtual lessons for curious minds. Amazon Explore Browse now. About the author Follow authors to get new release updates, plus improved recommendations. Ascent – Center for Technical Knowledge.

Brief content visible, double tap to read full content. Full content visible, double tap to read brief content. Read more Read less. Customer reviews. How customer reviews and ratings work Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them. Learn more how customers reviews work on Amazon. Top reviews Most recent Top reviews. Top reviews from the United States. There are 0 reviews and 0 ratings from the United States.

Top reviews from other countries. Verified Purchase. My only problem with the book was with the “Electrical” discipline. It was difficult learning to model in Revit in this discipline more often than the other two because there wasn’t as much referencing of the electrical elements – specifically, families – that were being used. When I tried to recreate some of the examples in the chapters, I kept getting errors.

Besides that, this book gives good examples AND explanations for specific scenarios. If you want to learn Revit MEP, this book is worth the purchase. It’s not perfect, but it will help you familiarize with the mechanical and plumbing disciplines.

Electrical leaves something to be said, however Report abuse. In the Type Selector, select Boiler: Standard. Note that the boiler automatically aligns to the wall, asshown in Figure 2— Click to place the component.

Save the project. The air terminals are automatically toggled off becauseyou are in a plumbing view, but the boiler is still displayedbecause Mechanical Equipment is typically toggled on.

In the Type Selector, select one of the wall-mounted waterclosets. Click along one of the walls to place the fixture, as shown inFigure 2— Return to the Type Selector and review the list. Note thatthere are sinks, but no lavatories.

In the Load Family dialog box, the Autodesk Revit familylibrary automatically displays. Basic Sketching and Modify Tools8. Place the lavatory against the wall across from the watercloset.

Click Modify and select the new fixture. Drag it up ordown until it meets with the alignment line of the WC, asshown in Figure 2— Click in space to release the selection. Task 3 – Place a lighting fixture and switch. Ensure that you are opening the Ceiling Plan so that theceiling grids display.

None of the previous elements that you have addeddisplay. In the Systems tab Electrical panel, clickFixture. Move the cursor over the grid. The light snaps to the gridlines, as shown in Figure 2— Press Spacebar to rotate the fixture. Click to place twofixtures in the room, as shown in Figure 2— Figure 2—26Figure 2— The light fixtures display in this view although you are seeinga plan view.

In the Systems tab Electrical panel, expand the Devicedrop-down list and select Lighting. Place the switch to the left of the door. It displays only as asymbol. Click Modify to end the command. Basic Sketching and Modify Tools2. The Autodesk Revit software was designed to makesuch changes quickly and efficiently. You can change an elementusing the methods shown in Figure 2—28, and described below:Type SelectorContextual TabPropertiesControls andconnectorsTemporary dimensionsFigure 2—28 Type Selector enables you to specify a different type.

Properties enables you to modify the information parameters associated with the selected elements. The contextual tab in the ribbon contains the Modifycommands and element-specific tools. Controls enable you to drag, flip, lock, and rotate the element. Autodesk Revit MEP Fundamentals Connectors control how related elements attach to anotherwith intelligence about size, needed fittings, and systeminformation.

MEP only Shape handles not shown enable you to drag elements tomodify their height or length. To delete an element, select it and press Delete , right-clickand select Delete, or in the Modify panel, click Delete.

Working with Controls and ConnectorsWhen you select an element, various controls and connectorsdisplay depending on the element and view. Using controls, youcan change an elements length or location, and flip or rotatesome elements. MEP connectors also provide information aboutattachments and enable you to add related elements, as shownfor creating pipe from a pipe accessory in Figure 2— Figure 2—29 2—20If you hover the cursor over the control or connector, a tooltipdisplays showing its function.

Tochange the location, you can drag the Witness Line control asshown in Figure 2—30 to connect to a new reference. You canalso click on the control to toggle between justifications in thewall. Before – connected tocenterline of wallAfter – connected toedge of wallFigure 2—30 The new location of a temporary dimension for an elementis remembered as long as you are in the same session ofthe software. To remove an element from a selection set, hold Shift andselect the element.

If you click and drag the cursor to window around elements,you have two selection options, as shown in Figure 2— Ifyou drag from left to right, you only select the elementscompletely inside the window. If you drag from right to left,you select elements both inside and crossing the window.

Window: Left to RightCrossing: Right to LeftFigure 2—31 If several elements are on or near each other, press Tab tocycle through them before you click. If there are elementsthat might be linked to each other, such as ductwork,pressing Tab selects the chain of elements. Press Ctrl Left Arrow to reselect the previous selectionset.

You can also right-click in the drawing window withnothing selected and select Select Previous. You do no have toselect an element, justhover over the one youwant to select.

Figure 2—33 Select links: When toggled on, you can selected linkeddrawings or Autodesk Revit models. When it is toggled offyou cannot select them when using Modify or Move. Select underlay elements: When toggled on, you canselect underlay elements. When toggled off, you cannotselect them when using Modify or Move. Select pinned elements: When toggled on, you canselected pinned elements. Select elements by face: When toggled on you canselect elements such as the floors or walls in an elevation by selecting the interior face or selecting an edge.

Whentoggled off, you can only select elements by selecting anedge. Drag elements on selection: When toggled on, youcan hover over an element, select it, and drag it to a newlocation. When toggled off, the Crossing or Box select modestarts when you press and drag, even if you are on top of anelement.

Once elements have been selected they can stillbe dragged to a new location. This gives you access to all ofthe Modify tools, and the Filter command. The Filter commandenables you to specify the types of elements to select. Forexample, you might only want to select lighting fixtures, asshown in Figure 2— Select everything in the required area.

The Filter dialog box opens, asshown in Figure 2— The Filter dialog boxdisplays all types ofelements in the originalselection. Basic Sketching and Modify Tools3. Click Check None to clear all of the options or Check All toselect all of the options.

You can also select or clearindividual categories as required. Click OK. The selection set is now limited to the elementsyou specified. In the Status Bar, the number of elements selected displaysbeside the Filter icon, as shown in Figure 2— You can alsosee the number of selected elements in the Propertiespalette. Use temporary dimensions and connectors to modify the location ofelements.

Estimated time forcompletion: 10 minutesIn this practice you will select lighting fixtures and change thetype as shown in Figure 2—37 , as well as test a variety ofselection methods and filters. You will then use connectors tomodify the location of an air terminal and use Create Similar toadd additional components.

You will also modify the height of theair terminals in Properties. Figure 2—37Task 1 – Use a variety of selection methods. In the practice files Basics folder, openSimple-Building-Edit. It opens in the 1 – Lighting view. Select one of the light fixtures.

Leave a Reply

Your email address will not be published. Required fields are marked *